The steam sterilizing agitator nutsche filter dryer designed by Wuxi Zhanghua Pharmaceutical Equipment is for the sterile production process, from inert, feeding slurry, cleaning, drying, to the discharge of dry products.
CIP and SIP provide safe and convenient sterilization solutions, and automatic operation is easy to check. This equipment is suitable for filtration and drying in biotechnology and pharmaceutical fields under sterile environment.
The steam sterilization agitator nutsche filter dryer can meet the requirements of verifiable sterile operation during the filtration and drying process of APIs, intermediates and fine chemicals.
Working principle
Before feeding the wet filter cake and filtrate, fill the container with nitrogen to remove the oxygen inside. This can prevent the potentially explosive atmosphere inside the container.
After inert, fill the filtrate in the container.
The filtrate is forced inside the container by nitrogen pressure, extending from the bottom of the filter cloth, the solids are retained on the cloth, and the mother liquid flows through the formed filter cake.
When the filtrate is separated from the filter cake, the cleaning process is started.
Before the replacement and washing, the surface of the filter cake is smoothed by agitator to prevent the filter cake from cracking.
The wash ring with nozzles evenly distributes the cleaning liquid over the surface of the entire filter cake. By re-pressurizing the container, the cleaning liquid flushes the filter cake, replaces the remaining mother liquid and drains the filtered mother liquid in the same way.
During the re-beating process, the cleaning liquid is added into the container and mixed with the material. By re-pressurizing the container, the cleaning liquid flushes the filter cake, replaces the remaining mother liquid and drains the filtered mother liquid in the same way.
After cleaning, the drying function is triggered. The vacuuming and heating of the dryer are carried out simultaneously for good effect. During the process, keep stirring the material and remain a state of vacuum and constant temperature (acceptable temperature of the material) until the humidity of the material reaches the requirement.
After dried, the material needs to be cooled before discharge.
The dried and cooled material is delivered to the discharge valve by the stirring arm and discharged through the valves on the side.
The cleaning liquid is sprayed onto the contact surface of the product by balls, and it is also used to clean the inside of the equipment between each individual production batch or when the product is changed, which is comprehensive and effective.
Features
Additional sensors and control systems to check when the sterilization process is over.
Verifiable sterilization performance
Flanges, seals and valves of all elements are in sterile class
Calculation, designand manufacture complies with Pressure Vessel Directive 97/23/EG, Section VIII of ASME Pressure Vessel Code, cGMP and FDA.
EG Type Examination Certificate 03ATEX0246X, UL verifiedElectronic Components
Double-layer mechanical seal and bellows, double-acting mechanical seal, contact or non-contact gas seal and liquid sealduring no-load operation
Sampling valve
Stainless steel hydraulic pre-wiring pipe, stainless steel pre-wiring on the junction box
Complete automatic online cleaning system (on-line cleaning and sterilization)
Options
Microwave heating function to shorten the drying process
Sterile version, residualremoval layer, isolator (glove box), DQ, IQ, OQ validation.
Fully automatic PLC control, connected to PMSX, strong current box.
Dryer |
Internal Area | Filtering Area | Nominal Volume | Volume of Filter Cake | Speed |
Drive |
PF 50 |
| 0.10 | 50 | 18 | 55 | 2.2 |
PF 100 | 500 | 0.20 | 100 | 32 | 50 | 4.0 |
PF 200 | 640 | 0.32 | 230 | 80 | 74 | 4.0 |
PF 250 | 700 | 0.38 | 280 | 115 | 70 | 5.5 |
PF 350 | 800 | 0.50 | 400 | 150 | 60 | 5.5 |
PF 500 S | 875 | 0.60 | 500 | 180 | 52 | 7.5 |
PF 500 | 955 | 0.70 | 640 | 210 | 46 | 7.5 |
PF 750 | 1050 | 0.85 | 770 | 340 | 40 | 7.5 |
PF 1000 S | 1150 | 1.00 | 930 | 415 | 40 | 11.0 |
PF 1000 | 1270 | 1.26 | 1140 | 505 | 37 | 11.0 |
PF 1500 | 1380 | 1.50 | 1500 | 750 | 30 | 15.0 |
PF 2000 | 1600 | 2.00 | 2000 | 1000 | 30 | 18.5 |
PF 2500 | 1800 | 2.50 | 2500 | 1250 | 25 | 18.5 |
PF 3000 | 1960 | 3.00 | 3000 | 1500 | 25 | 22 |
PF 4000 | 2260 | 4.00 | 4000 | 2000 | 21 | 22 |
PF 5000 | 2535 | 5.00 | 5000 | 2500 | 18 | 30 |
PF 6000 | 2765 | 6.00 | 6000 | 3000 | 17 | 30 |